Case Study · Water-loss Reduction

Water-loss reduction & quality improvement in Daruvar

Location
🇭🇷 Daruvar, Croatia
Year
2001
Funding
ECOLINKS (USA)
~⅓
Leakage cut to about a third of original
80/20
80% of losses on just 20% of the network
~33 km
Network modelled across 6 measurement zones
The challenge

High losses and no clear picture of the network

The water utility in Daruvar was losing a large share of its water and had no accurate, up-to-date picture of the distribution network. Without reliable data and a way to locate losses, it was difficult to plan effective interventions or justify investment.

The approach

Model, measurement and districting combined

Within an ECOLINKS-funded programme (USA), I combined desk modelling with intensive field work to find and reduce losses:

~33 km
Total network length
1
Gravity source (inflow 19.8–49.4 l/s)
6
Measurement zones
30–65 m
Pressure range across the network
Leakage level · before vs after
0 100% 100% BEFORE → ~⅓ AFTER
Leakage by zone
Zone Length [km] Leakage [l/s] Leakage [m³/year]
12.1300
23.920.154 730
34.610.515 768
4a0.167.5236 520
4b0.392.063 072
4c1.3800
4d0.342.166 226
4e0.390.26 307
4f3.933.5110 376
510.903.094 608
62.7200
Total30.8518.95597 607
Zone 4 (highlighted) concentrated the bulk of the losses — the basis for targeted, cost-effective leak repair.
The result

Losses brought down to about a third

Water losses were brought down to roughly a third of their original level, with 80% of the losses pinpointed on just 20% of the network length. The utility also gained a digital baseline of its network for day-to-day operation and future planning — turning a one-off project into a lasting operational asset.

Facing high water losses or planning network renewal?

Start a conversation See more references